HK 112M4 B5 4-6 IE3

E-Motor 400/690V 4,0kW 1460U B5 IE3
Product details for

HK 112M4 B5 4-6 IE3

P 50 Hz
4 kW
n 50 Hz
1,440 r/min
n 60 Hz
1,728 r/min
P 60 Hz
4.6 kW
LF 50 Hz
0.8
Factor IA / IN
7
η (IE3) %
89
H1
190 mm
B
401 mm
I 50 Hz
14 A
Ø D shaft
28 mm
Ø E
180 mm
Ø F
250 mm
All characteristics

Characteristics

Ambient temperature
  • -20 °C to +40 °C 
Protection IP
  • IP 55 
Material
  • housing: aluminium 
  • housing: grey cast iron (from HK160...) 
Design
  • Type B5 
  • without feet 
Customs tariff number
  • 85015220 
All characteristics

Product description

Notes
Achtung! Maß »B« kann je nach Ausführung geringfügig länger ausfallen.
Description
Eigengekühlte Käfigläufer-Energiesparmotoren
High Efficiency IE3 - IEC60034-30:2009
Bemessungsspannung 400/690 V 50 Hz, 460 V 60 Hz
4-polig
Spannungstoleranz ±5 %
Alle Motoren inklusive Thermoschutz (PTC Kaltleiter).

Product variants

11 Results
Show dimensional drawing
Identifier
P 50 Hz (kW)
n 50 Hz (r/min)
n 60 Hz (r/min)
P 60 Hz (kW)
P 60 Hz = Nennleistung bei 400 V/60 Hz
n 50 Hz = Nenndrehzahl bei 400 V/50 Hz
n 60 Hz = Nenndrehzahl bei 400 V/60 Hz
I 50 Hz = Nennstrom bei 400 V/50 Hz
LF 50 Hz = Leistungsfaktor cos phi bei 50 Hz
P 50 Hz = Nennleistung bei 400 V/50 Hz
η (IE3) = Wirkungsgrad nach IE3 in % (bei Volllast)
Faktor IA/IN = Anlaufstrom IA / Nennstrom IN

Shows 10 of 11

Column selection

P 50 Hz (kW)
n 50 Hz (r/min)
n 60 Hz (r/min)
P 60 Hz (kW)
LF 50 Hz
Faktor IA/IN
η (IE3) %
H1 (mm)
B (mm)
I 50 Hz (A)
Ø D Welle (mm)
Ø E (mm)
Ø F (mm)
P 60 Hz = Nennleistung bei 400 V/60 Hz
n 50 Hz = Nenndrehzahl bei 400 V/50 Hz
n 60 Hz = Nenndrehzahl bei 400 V/60 Hz
I 50 Hz = Nennstrom bei 400 V/50 Hz
LF 50 Hz = Leistungsfaktor cos phi bei 50 Hz
P 50 Hz = Nennleistung bei 400 V/50 Hz
η (IE3) = Wirkungsgrad nach IE3 in % (bei Volllast)
Faktor IA/IN = Anlaufstrom IA / Nennstrom IN