HK 132SB4 B5 4-6 IE3

E-Motor 400/690V 5,5kW 1470U B5 IE3
Product details for

HK 132SB4 B5 4-6 IE3

P 50 Hz
5,5 kW
n 50 Hz
1.460 r/min
n 60 Hz
1.752 r/min
P 60 Hz
6,3 kW
LF 50 Hz
0,8
Faktor IA/IN
7,1
η (IE3) %
90
H1
215 mm
B
422 mm
I 50 Hz
11,1 A
Ø D Welle
38 mm
Ø E
230 mm
Ø F
300 mm
All characteristics

Characteristics

Schutzart
  • IP 55 
Umgebungstemperatur
  • -20 °C bis +40 °C 
Werkstoff
  • Gehäuse: Aluminium 
  • Gehäuse: Grauguss (ab HK160...) 
Ausführung
  • Bauform B5 
  • ohne Füße 
Zolltarifnummer
  • 85015220 
All characteristics

Product description

Notes
Achtung! Maß »B« kann je nach Ausführung geringfügig länger ausfallen.
Description
Eigengekühlte Käfigläufer-Energiesparmotoren
High Efficiency IE3 - IEC60034-30:2009
Bemessungsspannung 400/690 V 50 Hz, 460 V 60 Hz
4-polig
Spannungstoleranz ±5 %
Alle Motoren inklusive Thermoschutz (PTC Kaltleiter).

Product variants

11 Results
Show dimensional drawing
Identifier
P 50 Hz (kW)
n 50 Hz (r/min)
n 60 Hz (r/min)
P 60 Hz (kW)
7,5 kW
1 470 r/min
1 770 r/min
8,6 kW
11 kW
1 470 r/min
1 770 r/min
12,6 kW
15 kW
1 470 r/min
1 770 r/min
17,3 kW
18,5 kW
1 475 r/min
1 775 r/min
21,3 kW
22 kW
1 475 r/min
1 775 r/min
25,3 kW
30 kW
1 475 r/min
1 775 r/min
34,5 kW
37 kW
1 480 r/min
1 780 r/min
42,5 kW
P 60 Hz = Nennleistung bei 400 V/60 Hz
n 50 Hz = Nenndrehzahl bei 400 V/50 Hz
n 60 Hz = Nenndrehzahl bei 400 V/60 Hz
I 50 Hz = Nennstrom bei 400 V/50 Hz
LF 50 Hz = Leistungsfaktor cos phi bei 50 Hz
P 50 Hz = Nennleistung bei 400 V/50 Hz
η (IE3) = Wirkungsgrad nach IE3 in % (bei Volllast)
Faktor IA/IN = Anlaufstrom IA / Nennstrom IN

Shows 10 of 11

Column selection

P 50 Hz (kW)
n 50 Hz (r/min)
n 60 Hz (r/min)
P 60 Hz (kW)
LF 50 Hz
Factor IA / IN
η (IE3) %
H1 (mm)
B (mm)
I 50 Hz (A)
Ø D arbre (mm)
Ø E (mm)
Ø F (mm)
P 60 Hz = Nennleistung bei 400 V/60 Hz
n 50 Hz = Nenndrehzahl bei 400 V/50 Hz
n 60 Hz = Nenndrehzahl bei 400 V/60 Hz
I 50 Hz = Nennstrom bei 400 V/50 Hz
LF 50 Hz = Leistungsfaktor cos phi bei 50 Hz
P 50 Hz = Nennleistung bei 400 V/50 Hz
η (IE3) = Wirkungsgrad nach IE3 in % (bei Volllast)
Faktor IA/IN = Anlaufstrom IA / Nennstrom IN